Back To Products

GZ0741SA Manually Controlled Step Attenuator

 

Technical Specifications

Parameters Value Step
Frequency Range, GHz 0-7  
Attenuation Range, dB 0-41  1
Attenuation Accuracy @ DC    
          for sections 1-10 dB ±0,2 dB  
          for section 20 dB ±0,4 dB  
Attenuation Accuracy in Frequency Range 1- 4 GHz  
          for sections 1-10 dB ±1,0 dB  
          for section 20 dB  ±1,5 dB  
Attenuation Accuracy in Frequency Range 4- 7 GHz  
          for sections 1-10 dB ±1,2 dB  
          for section 20 dB ±3,0 dB
I/O Impedance, Ohm  50±0,5  
Type of I/O Connectors N-Type
female
Maximum Dissipation DC Power, W 1
Maximum Dissipation Peak Power, W 25  
Operating temperature range, C 5...40  

 

 